| Availability: | |
|---|---|
| Quantity: | |
NDR-150
FUNELEC
| Model | NDR-150-12 | NDR-150-24 | |
| Output | DC output Voltage | 12V | 24V |
| Voltage tolerance | ±1.0% | ±1.0% | |
| Rated Current | 12.5A | 6.25A | |
| Related Power | 150w | 150w | |
| Wave&Noise | 80mVp-p | 150mVp-p | |
| Adjustable range for DC Voltage | ±10% | ±10% | |
| Set up,rise,hold up time | 800ms 600ms 50ms | ||
| Input | Voltage Range | 85 ~ 264VAC 47-63HZ 120-370VDC | |
| Input Current | 1A/115VAC 0.5A/230VAC | ||
| Efficiency | 77% | 82% | |
| AC inrush current | Cold start current 15A/115V 30A /230VAC | ||
| Leakage current | <0.5mA/240VAC | ||
| Protection | Overload | Related output power 105-135% start overload protection | |
| Protection type: cutoff output, recovery after restart power | |||
| Over voltage | 13.8V-16.2V | 27.6V-32.4V | |
| Hiccup mode,recovers automatically after fault condition | |||
| Environment | Working temp humidity | -10~+60°C 20%~90%RH | |
| Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | ||
| Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |
| I/P-FG:1.5KVAC 1min | |||
| O/P-FG:0.5KVAC 1min | |||
| Standard | Safety standard | Fit UL1012 | |
| Refer | Design refer to GB4943,UL60950,EN60950 | ||
| EMC standard | Design refer to GB9254,EN55022 Class A | ||
| Size | size | 40*W125.5*H113.5mm | |
| Package | 0.56kg, | ||
| Model | NDR-150-12 | NDR-150-24 | |
| Output | DC output Voltage | 12V | 24V |
| Voltage tolerance | ±1.0% | ±1.0% | |
| Rated Current | 12.5A | 6.25A | |
| Related Power | 150w | 150w | |
| Wave&Noise | 80mVp-p | 150mVp-p | |
| Adjustable range for DC Voltage | ±10% | ±10% | |
| Set up,rise,hold up time | 800ms 600ms 50ms | ||
| Input | Voltage Range | 85 ~ 264VAC 47-63HZ 120-370VDC | |
| Input Current | 1A/115VAC 0.5A/230VAC | ||
| Efficiency | 77% | 82% | |
| AC inrush current | Cold start current 15A/115V 30A /230VAC | ||
| Leakage current | <0.5mA/240VAC | ||
| Protection | Overload | Related output power 105-135% start overload protection | |
| Protection type: cutoff output, recovery after restart power | |||
| Over voltage | 13.8V-16.2V | 27.6V-32.4V | |
| Hiccup mode,recovers automatically after fault condition | |||
| Environment | Working temp humidity | -10~+60°C 20%~90%RH | |
| Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | ||
| Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |
| I/P-FG:1.5KVAC 1min | |||
| O/P-FG:0.5KVAC 1min | |||
| Standard | Safety standard | Fit UL1012 | |
| Refer | Design refer to GB4943,UL60950,EN60950 | ||
| EMC standard | Design refer to GB9254,EN55022 Class A | ||
| Size | size | 40*W125.5*H113.5mm | |
| Package | 0.56kg, | ||