DR-120
FUNELEC
| Model | DR-120-12 | DR-120-24 | DR-120-48 | |
| Output | DC output Voltage | 12V | 24V | 48V |
| Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | |
| Rated Current | 10A | 5A | 2.5A | |
| Related Power | 120w | 120w | 120w | |
| Wave&Noise | 80mVp-p | 80mVp-p | 150mVp-p | |
| Adjustable range for DC Voltage | ±10% | ±10% | ±10% | |
| Set up,rise,hold up time | 800ms 600ms 50ms | |||
| Input | Voltage Range | 85 ~ 264VAC 47-63HZ 120-370VDC | ||
| Input Current | 4A/115VAC 0.5A/230VAC | |||
| Efficiency | 80% | 84% | 85% | |
| AC inrush current | Cold start current 15A/115V 30A /230VAC | |||
| Leakage current | <0.5mA/240VAC | |||
| Protection | Overload | Related output power 105-135% start overload protection | ||
| Protection type: cutoff output, recovery after restart power | ||||
| Over voltage | 13.8V-16.2V | 27.6V-32.4V | 55.2V-64.8V | |
| Hiccup mode,recovers automatically after fault condition | ||||
| Environment | Working temp humidity | -10~+60°C 20%~90%RH | ||
| Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |||
| Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | ||
| I/P-FG:1.5KVAC 1min | ||||
| O/P-FG:0.5KVAC 1min | ||||
| Standard | Safety standard | Fit UL1012 | ||
| Refer | Design refer to GB4943,UL60950,EN60950 | |||
| EMC standard | Design refer to GB9254,EN55022 Class A | |||
| Size | size | L100*W66*H125mm | ||
| Package | 0.8kg, | |||
| Model | DR-120-12 | DR-120-24 | DR-120-48 | |
| Output | DC output Voltage | 12V | 24V | 48V |
| Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | |
| Rated Current | 10A | 5A | 2.5A | |
| Related Power | 120w | 120w | 120w | |
| Wave&Noise | 80mVp-p | 80mVp-p | 150mVp-p | |
| Adjustable range for DC Voltage | ±10% | ±10% | ±10% | |
| Set up,rise,hold up time | 800ms 600ms 50ms | |||
| Input | Voltage Range | 85 ~ 264VAC 47-63HZ 120-370VDC | ||
| Input Current | 4A/115VAC 0.5A/230VAC | |||
| Efficiency | 80% | 84% | 85% | |
| AC inrush current | Cold start current 15A/115V 30A /230VAC | |||
| Leakage current | <0.5mA/240VAC | |||
| Protection | Overload | Related output power 105-135% start overload protection | ||
| Protection type: cutoff output, recovery after restart power | ||||
| Over voltage | 13.8V-16.2V | 27.6V-32.4V | 55.2V-64.8V | |
| Hiccup mode,recovers automatically after fault condition | ||||
| Environment | Working temp humidity | -10~+60°C 20%~90%RH | ||
| Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |||
| Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | ||
| I/P-FG:1.5KVAC 1min | ||||
| O/P-FG:0.5KVAC 1min | ||||
| Standard | Safety standard | Fit UL1012 | ||
| Refer | Design refer to GB4943,UL60950,EN60950 | |||
| EMC standard | Design refer to GB9254,EN55022 Class A | |||
| Size | size | L100*W66*H125mm | ||
| Package | 0.8kg, | |||